CVE-2025-22961

8.0 HIGH
Published: February 13, 2025 Modified: April 15, 2026
View on NVD

Description

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.

AI Explanation

Get an AI-powered plain-language explanation of this vulnerability and remediation steps.

Login to generate AI explanation

CVSS v3.x Details

0.0 Low Medium High Critical 10.0
Vector String
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

References to Advisories, Solutions, and Tools

Patch Vendor Advisory Exploit Third Party Advisory

1 reference(s) from NVD

Quick Stats

CVSS v3 Score
8.0 / 10.0
EPSS (Exploit Probability)
0.3%
50th percentile
Exploitation Status
Not in CISA KEV

Weaknesses (CWE)