Search and browse vulnerability records from NVD
Showing 50 of 115067 CVEs
| CVE ID | Severity | Description | EPSS | Published | |
|---|---|---|---|---|---|
| 5.1 MEDIUM |
Buffer overflow vulnerability in H3C FA3010L access points SWFA1B0V100R005 due to the lack of length verification, which is related to the setting of firewall rules. Attackers who successfully exploit this vulnerability can cause the remote target device to crash or execute arbitrary commands. |
0.1% | 2025-02-11 | ||
| 7.3 HIGH |
A DLL hijacking vulnerability in the AMD Ryzen™ Master Utility could allow an attacker to achieve privilege escalation, potentially resulting in arbitrary code execution. |
0.0% | 2025-02-11 | ||
| 7.3 HIGH |
A DLL hijacking vulnerability in AMD Integrated Management Technology (AIM-T) Manageability Service could allow an attacker to achieve privilege escalation potentially resulting in arbitrary code execution. |
0.0% | 2025-02-11 | ||
| 7.3 HIGH |
Incorrect default permissions in the AMD Integrated Management Technology (AIM-T) Manageability Service installation directory could allow an attacker to achieve privilege escalation, potentially resulting in arbitrary code execution. |
0.0% | 2025-02-11 | ||
| 5.1 MEDIUM |
A security issue in Sitevision version 10.3.1 and older allows a remote attacker, in certain (non-default) scenarios, to gain access to the private keys used for signing SAML Authn requests. The underlying issue is a Java keystore that may become accessible and downloadable via WebDAV. This keystore is protected with a low-complexity, auto-generated password. |
0.2% | 2025-02-11 | ||
| 7.5 HIGH |
Cleartext Storage of Sensitive Information vulnerability in Salesforce Tableau Server can record the Personal Access Token (PAT) into logging repositories.This issue affects Tableau Server: before 2022.1.3, before 2021.4.8, before 2021.3.13, before 2021.2.14, before 2021.1.16, before 2020.4.19. |
0.1% | 2025-02-11 | ||
| 7.7 HIGH |
Server-Side Request Forgery (SSRF) vulnerability in Salesforce Tableau Server allows Authentication Bypass.This issue affects Tableau Server: from 2023.3 through 2023.3.5. |
0.1% | 2025-02-11 | ||
|
CVE-2025-21418
KEV
|
7.8 HIGH |
Windows Ancillary Function Driver for WinSock Elevation of Privilege Vulnerability |
13.3% | 2025-02-11 | |
|
CVE-2025-21391
KEV
|
7.1 HIGH |
Windows Storage Elevation of Privilege Vulnerability |
4.8% | 2025-02-11 | |
|
CVE-2025-24472
KEV
|
8.1 HIGH |
An Authentication Bypass Using an Alternate Path or Channel vulnerability [CWE-288] affecting FortiOS 7.0.0 through 7.0.16 and FortiProxy 7.2.0 through 7.2.12, 7.0.0 through 7.0.19 may allow a remote unauthenticated attacker with prior knowledge of upstream and downstream devices serial numbers to gain super-admin privileges on the downstream device, if the Security Fabric is enabled, via crafted CSF proxy requests. |
10.1% | 2025-02-11 | |
| 7.9 HIGH |
Dell UCC Edge, version 2.3.0, contains a Blind SSRF on Add Customer SFTP Server vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Server-side request forgery |
0.1% | 2025-02-11 | ||
| 9.3 CRITICAL |
A Reliance on Untrusted Inputs in a Security Decision vulnerability has been identified in the Lexmark Print Management Client. |
0.0% | 2025-02-11 | ||
| 7.1 HIGH |
An improper neutralization of input during web page generation ('cross-site scripting') vulnerability in Fortinet FortiSandbox 4.4.0 through 4.4.4, FortiSandbox 4.2.1 through 4.2.6, FortiSandbox 4.0.0 through 4.0.4, FortiSandbox 3.2 all versions, FortiSandbox 3.1 all versions, FortiSandbox 3.0 all versions allows an authenticated attacker to execute unauthorized code or commands via crafted HTTP requests. |
7.5% | 2025-02-11 | ||
| 7.3 HIGH |
An HTML Injection vulnerability in Avaya Spaces may have allowed disclosure of sensitive information or modification of the page content seen by the user. |
0.1% | 2025-02-11 | ||
| 6.7 MEDIUM |
A use of externally-controlled format string vulnerability [CWE-134] vulnerability in Fortinet allows a privileged attacker to execute arbitrary code or commands via specially crafted requests. |
0.0% | 2025-02-11 | ||
| N/A |
Distribution is a toolkit to pack, ship, store, and deliver container content. Systems running registry versions 3.0.0-beta.1 through 3.0.0-rc.2 with token authentication enabled may be vulnerable to an issue in which token authentication allows an attacker to inject an untrusted signing key in a JSON web token (JWT). The issue lies in how the JSON web key (JWK) verification is performed. When a JWT contains a JWK header without a certificate chain, the code only checks if the KeyID (`kid`) matches one of the trusted keys, but doesn't verify that the actual key material matches. A fix for the issue is available at commit 5ea9aa028db65ca5665f6af2c20ecf9dc34e5fcd and expected to be a part of version 3.0.0-rc.3. There is no way to work around this issue without patching if the system requires token authentication. |
0.1% | 2025-02-11 | ||
| 9.3 CRITICAL |
Concorde, formerly know as Nexkey, is a fork of the federated microblogging platform Misskey. Prior to version 12.25Q1.1, due to an improper implementation of the logout process, authentication credentials remain in cookies even after a user has explicitly logged out, which may allow an attacker to steal authentication tokens. This could have devastating consequences if a user with admin privileges is (or was) using a shared device. Users who have logged in on a shared device should go to Settings > Security and regenerate their login tokens. Version 12.25Q1.1 fixes the issue. As a workaround, clear cookies and site data in the browser after logging out. |
0.1% | 2025-02-11 | ||
| 8.6 HIGH |
Concorde, formerly know as Nexkey, is a fork of the federated microblogging platform Misskey. Due to a lack of CSRF countermeasures and improper settings of cookies for MediaProxy authentication, there is a vulnerability that allows MediaProxy authentication to be bypassed. In versions prior to 12.25Q1.1, the authentication cookie does not have the SameSite attribute. This allows an attacker to bypass MediaProxy authentication and load any image without restrictions under certain circumstances. In versions prior to 12.24Q2.3, this cookie was also used to authenticate the job queue management page (bull-board), so bull-board authentication is also bypassed. This may enable attacks that have a significant impact on availability and integrity. The affected versions are too old to be covered by this advisory, but the maintainers of Concorde strongly recommend not using older versions. Version 12.25Q1.1 contains a patch. There is no effective workaround other than updating. |
0.1% | 2025-02-11 | ||
| 8.2 HIGH |
Misskey is an open source, federated social media platform. Starting in version 12.109.0 and prior to version 2025.2.0-alpha.0, due to a lack of CSRF protection and the lack of proper security attributes in the authentication cookies of Bull's dashboard, some of the APIs of bull-board may be subject to CSRF attacks. There is a risk of this vulnerability being used for attacks with relatively large impact on availability and integrity, such as the ability to add arbitrary jobs. This vulnerability was fixed in 2025.2.0-alpha.0. As a workaround, block all access to the `/queue` directory with a web application firewall (WAF). |
0.0% | 2025-02-11 | ||
| 6.3 MEDIUM |
Issue summary: Clients using RFC7250 Raw Public Keys (RPKs) to authenticate a server may fail to notice that the server was not authenticated, because handshakes don't abort as expected when the SSL_VERIFY_PEER verification mode is set. Impact summary: TLS and DTLS connections using raw public keys may be vulnerable to man-in-middle attacks when server authentication failure is not detected by clients. RPKs are disabled by default in both TLS clients and TLS servers. The issue only arises when TLS clients explicitly enable RPK use by the server, and the server, likewise, enables sending of an RPK instead of an X.509 certificate chain. The affected clients are those that then rely on the handshake to fail when the server's RPK fails to match one of the expected public keys, by setting the verification mode to SSL_VERIFY_PEER. Clients that enable server-side raw public keys can still find out that raw public key verification failed by calling SSL_get_verify_result(), and those that do, and take appropriate action, are not affected. This issue was introduced in the initial implementation of RPK support in OpenSSL 3.2. The FIPS modules in 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue. |
0.8% | 2025-02-11 | ||
| 8.8 HIGH |
AMI APTIOV contains a vulnerability in BIOS where an attacker may cause an Improper Input Validation by a local attacker. Successful exploitation of these vulnerabilities may lead to overwriting arbitrary memory and execute arbitrary code at SMM level, also impacting Confidentiality, Integrity, and Availability. |
0.1% | 2025-02-11 | ||
| 9.8 CRITICAL |
PandasAI uses an interactive prompt function that is vulnerable to prompt injection and run arbitrary Python code that can lead to Remote Code Execution (RCE) instead of the intended explanation of the natural language processing by the LLM. |
5.9% | 2025-02-11 | ||
| 6.5 MEDIUM |
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
0.0% | 2025-02-11 | ||
| 7.5 HIGH |
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device. |
0.1% | 2025-02-11 | ||
| 4.3 MEDIUM |
A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices with role `user` is affected by incorrect authorization in SNMPv3 View configuration. This could allow an attacker to change the View Type of SNMPv3 Views. |
0.1% | 2025-02-11 | ||
| 7.2 HIGH |
A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly validate input while loading the configuration files. This could allow an authenticated remote attacker to execute arbitrary shell commands on the device. |
0.2% | 2025-02-11 | ||
| 7.0 HIGH |
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures. |
0.0% | 2025-02-11 | ||
| 4.9 MEDIUM |
The SuperSaaS – online appointment scheduling plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘after’ parameter in all versions up to, and including, 2.1.12 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. This is limited to Chromium-based browsers (e.g. Chrome, Edge, Brave). |
0.1% | 2025-02-11 | ||
| 5.9 MEDIUM |
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state. |
0.1% | 2025-02-11 | ||
| 7.5 HIGH |
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext. |
0.0% | 2025-02-11 | ||
| 7.5 HIGH |
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
0.1% | 2025-02-11 | ||
| 4.6 MEDIUM |
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |
0.0% | 2025-02-11 | ||
| 6.8 MEDIUM |
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device. |
0.1% | 2025-02-11 | ||
| 8.8 HIGH |
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SIMOCODE ES V19 (All versions < V19 Update 1), SIRIUS Safety ES V19 (TIA Portal) (All versions < V19 Update 1), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions < V19 Update 1), TIA Administrator (All versions < V3.0.4). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout. |
0.2% | 2025-02-11 | ||
| 5.3 MEDIUM |
The integrated ICMP service of the network stack of affected devices can be forced to exhaust its available memory resources when receiving specially crafted messages targeting IP fragment re-assembly. This could allow an unauthenticated remote attacker to cause a temporary denial of service condition of the ICMP service, other communication services are not affected. Affected devices will resume normal operation after the attack terminates. |
0.3% | 2025-02-11 | ||
| 6.4 MEDIUM |
The GeoDirectory – WP Business Directory Plugin and Classified Listings Directory plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the display_name profile parameter in all versions up to, and including, 2.8.97 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Subscriber-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. |
0.1% | 2025-02-11 | ||
| 5.3 MEDIUM |
The login functionality of the web server in affected devices does not normalize the response times of login attempts. An unauthenticated remote attacker could exploit this side-channel information to distinguish between valid and invalid usernames. |
0.1% | 2025-02-11 | ||
| 8.8 HIGH |
An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web interface to be able to conduct this attack. This issue is fixed in recent firmware versions BSP >= 6.1.0. |
0.3% | 2025-02-11 | ||
| 9.8 CRITICAL |
The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
0.3% | 2025-02-11 | ||
| 6.8 MEDIUM |
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. |
0.2% | 2025-02-11 | ||
| 6.1 MEDIUM |
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected. |
0.2% | 2025-02-11 | ||
| 4.6 MEDIUM |
Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data. |
0.0% | 2025-02-11 | ||
| 8.8 HIGH |
The Zox News - Professional WordPress News & Magazine Theme plugin for WordPress is vulnerable to unauthorized data modification. This vulnerability can lead to privilege escalation and denial of service conditions due to missing capability checks on the backup_options() and reset_options() functions in all versions up to and including 3.17.0. This vulnerability allows authenticated attackers with Subscriber-level access and above to update and delete arbitrary option values on the WordPress site. Attackers can exploit this issue to update the default user role for registration to Administrator and enable user registration, thereby gaining administrative access to the vulnerable site. Additionally, they could delete critical options, causing errors that may disrupt the site's functionality and deny service to legitimate users. |
0.1% | 2025-02-11 | ||
| 9.8 CRITICAL |
The WP Foodbakery plugin for WordPress is vulnerable to privilege escalation via account takeover in all versions up to, and including, 4.8. This is due to the plugin not properly validating a user's identity prior to setting the current user and their authentication cookie. This makes it possible for unauthenticated attackers to gain access to a target user's (e.g. administrators) account. |
0.3% | 2025-02-11 | ||
| 9.8 CRITICAL |
The WP Foodbakery plugin for WordPress is vulnerable to privilege escalation in all versions up to, and including, 4.7. This is due to the plugin not properly restricting what user meta can be updated during profile registration. This makes it possible for unauthenticated attackers to register on the site as an administrator. |
0.3% | 2025-02-11 | ||
| 6.5 MEDIUM |
Versions of the package hackney before 1.21.0 are vulnerable to Server-side Request Forgery (SSRF) due to improper parsing of URLs by URI built-in module and hackey. Given the URL http://127.0.0.1?@127.2.2.2/, the URI function will parse and see the host as 127.0.0.1 (which is correct), and hackney will refer the host as 127.2.2.2/. This vulnerability can be exploited when users rely on the URL function for host checking. |
0.0% | 2025-02-11 | ||
| 6.4 MEDIUM |
The HT Mega – Absolute Addons For Elementor plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the plugin's Countdown widget in all versions up to, and including, 2.8.1 due to insufficient input sanitization and output escaping on user supplied attributes. This makes it possible for authenticated attackers, with contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. |
0.1% | 2025-02-11 | ||
| 3.5 LOW |
A vulnerability classified as problematic was found in code-projects Real Estate Property Management System 1.0. Affected by this vulnerability is an unknown functionality of the file /Admin/CustomerReport.php. The manipulation of the argument Address leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |
0.2% | 2025-02-11 | ||
| 6.1 MEDIUM |
NetVision Information ISOinsight has a Reflected Cross-site Scripting vulnerability, allowing unauthenticated remote attackers to execute arbitrary JavaScript code in the user's browser through phishing techniques. |
0.4% | 2025-02-11 | ||
| 9.8 CRITICAL |
School Affairs System from Quanxun has an Exposure of Sensitive Information, allowing unauthenticated attackers to view specific pages and obtain database information as well as plaintext administrator credentials. |
0.3% | 2025-02-11 |